• Standard Sensors for detecting ferrous metals.
• Wide array of variations. Ideal for a variety of applications.
• Models with different frequencies are also available to prevent mutual interference.
• Superior environment resistance with standard cable made of oilresistant PVC and sensing surface made of material that resists cutting oil.
• Useful to help prevent disconnection. Cable protector provided as a standard feature.
2-Wire Models
Pre-wired Models with Oil-resistant Reinforced PUR Cables Added to the Lineup and Easy Differentiation with Orange Head
Lineup includes models with Smartclick pre-wired connectors for fast connection.
UL-recognized Models Available
Specification
E2E-X[]D[] DC 2-Wire Models
Size | M8 | M12 | |||
---|---|---|---|---|---|
Shielded | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2E-X2D[] | E2E-X4MD[] | E2E-X3D[] | E2E-X8MD[] | |
Sensing distance | 2 mm ±10% | 4 mm ±10% | 3 mm ±10% | 8 mm ±10% | |
Set distance *1 | 0 to 1.6 mm | 0 to 3.2 mm | 0 to 2.4 mm | 0 to 6.4 mm | |
Differential travel | 15% max. of sensing distance | 10% max. of sensing distance | |||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) |
||||
Standard sensing object | Iron, 8 × 8 × 1 mm |
Iron, 20 × 20 × 1 mm |
Iron, 12 × 12 × 1 mm |
Iron, 30 × 30 × 1 mm |
|
Response frequency *2 | 1.5 kHz | 1 kHz | 0.8 kHz | ||
Power supply voltage (operating voltage range) |
Standard Models: 12 to 24 VDC, ripple (p-p): 10% max. (10 to 30 VDC) US Models and Connector Models Used as UL-certified Models: 12 to 24 VDC, ripple (p-p): 10% max. (The operating voltage range is also the same.) *3 |
||||
Leakage current | 0.8 mA max. | ||||
Control output |
Load current | 3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models | |||
Residual voltage *4 |
3 V max. (Load current: 100 mA, Cable length: 2 m, M1J-T Models only: 5 V max.) | ||||
Indicators | D1 Models: Operation indicator (red) and setting indicator (green) D2 Models: Operation indicator (red) |
||||
Operation mode (with sensing object approaching) |
D1 Models: NO D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. |
||||
Diagnostic output delay | 0.3 to 1 s | ||||
Protection circuits | Surge suppressor, Load short-circuit protection (for control and diagnostic output) | ||||
Ambient temperature range |
Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | ||||
Ambient humidity range | Operating/storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
|||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1000 VAC, 50/60 Hz for 1 minute between current carry parts and case | ||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
Shock resistance | Destruction: 500 m/s2 10 times each in X, Y, and Z directions |
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions |
|||
Degree of protection | Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant Connector Models: IEC 60529 IP67 |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired Connector Models (Standard cable length: 0.3 m) |
||||
Weight (packed state) |
Pre-wired Models |
Approx. 60 g | Approx. 70 g | ||
Pre-wired Connector Models |
— | Approx. 40 g | |||
Connector Models |
Approx. 15 g | Approx. 25 g | |||
Materi- als |
Case | Stainless steel (SUS303) | Nickel-plated brass | ||
Sensing surface | PBT | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washer | Zinc-plated iron | ||||
Accessories | Instruction manual |
Size | M18 | M30 | |||
---|---|---|---|---|---|
Shielded | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2E-X7D[] | E2E-X14MD[] | E2E-X10D[] | E2E-X20MD[] | |
Sensing distance | 7 mm ±10% | 14 mm ±10% | 10 mm ±10% | 20 mm ±10% | |
Set distance *1 | 0 to 5.6 mm | 0 to 11.2 mm | 0 to 8 mm | 0 to 16 mm | |
Differential travel | 10% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) |
||||
Standard sensing object | Iron, 18 × 18 × 1 mm |
Iron, 30 × 30 × 1 mm | Iron, 54 × 54 × 1 mm |
||
Response frequency *2 | 0.5 kHz | 0.4 kHz | 0.1 kHz | ||
Power supply voltage (operating voltage range) |
Standard Models: 12 to 24 VDC, ripple (p-p): 10% max. (10 to 30 VDC) US Models and Connector Models Used as UL-certified Models: 12 to 24 VDC, ripple (p-p): 10% max. (The operating voltage range is also the same.) *3 |
||||
Leakage current | 0.8 mA max. | ||||
Control output |
Load current | 3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models | |||
Residual voltage *4 |
3 V max. (Load current: 100 mA, Cable length: 2 m, M1J-T Models only: 5 V max.) | ||||
Indicators | D1 Models: Operation indicator (red) and setting indicator (green) D2 Models: Operation indicator (red) |
||||
Operation mode (with sensing object approaching) |
D1 Models: NO D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. |
||||
Diagnostic output delay | 0.3 to 1 s | ||||
Protection circuits | Surge suppressor, Load short-circuit protection (for control and diagnostic output) | ||||
Ambient temperature range |
Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | ||||
Ambient humidity range | Operating/storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1000 VAC, 50/60 Hz for 1 minute between current carry parts and case | ||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | ||||
Degree of protection | Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant Connector Models: IEC 60529 IP67 |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired Connector Models (Standard cable length: 0.3 m) |
||||
Weight (packed state) |
Pre-wired Models |
Approx. 130 g | Approx. 175 g | ||
Pre-wired Connector Models |
Approx. 70 g | Approx. 110 g | |||
Connector Models |
Approx. 40 g | Approx. 90 g | |||
Materi- als |
Case | Nickel-plated brass | |||
Sensing surface | PBT | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washer | Zinc-plated iron | ||||
Accessories | Instruction manual |
*1. Use the E2E within the range in which the setting indicator (green LED) is ON (except D2 Models).
*2. The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object,
and a set distance of half the sensing distance.
*3. For the information on UL-certified connector models, refer to your OMRON website.
*4. The residual voltage of each M1J-T Model is 5 V. When connecting to a device, make sure that the device can
withstand the residual voltage. (Refer to page 26 for details.)
E2E-X[]Y[] AC 2-Wire Models
Size | M8 | M12 | |||
---|---|---|---|---|---|
Shielded | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2E-X1R5Y[] | E2E-X2MY[] | E2E-X2Y[] | E2E-X5MY[] | |
Sensing distance | 1.5 mm ±10% | 2 mm ±10% | 5 mm ±10% | ||
Set distance | 0 to 1.2 mm | 0 to 1.6 mm | 0 to 4 mm | ||
Differential travel | 10% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) |
||||
Standard sensing object | Iron, 8 × 8 × 1 mm |
Iron, 12 × 12 × 1 mm | Iron, 15 × 15 × 1 mm |
||
Response frequency | 25 Hz | ||||
Power supply voltage (operating voltage range) *1 |
24 to 240 VAC (20 to 264 VAC), 50/60 Hz | ||||
Leakage current | 1.7 mA max. | ||||
Control output |
Load current *2 | 5 to 100 mA | 5 to 200 mA | ||
Residual voltage | Refer to Engineering Data on Data Sheet. | ||||
Indicators | Operation indicator (red) | ||||
Operation mode (with sensing object approaching) |
Y1 Models: NO Y2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. |
||||
Protection circuits | Surge suppressor | ||||
Ambient temperature range *1 *2 |
Operating/Storage: -25 to 70°C (with no icing or condensation) |
Operating/Storage: -40 to 85°C (with no icing or condensation) |
|||
Ambient humidity range | Operating/storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C, ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
|||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 4,000 VAC (M8 Models: 2,000 VAC), 50/60 Hz for 1 min between current-carrying parts and case |
||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
Shock resistance | Destruction: 500 m/s2 10 times each in X, Y, and Z directions |
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions |
|||
Degree of protection | Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant Connector Models: IEC 60529 IP67 |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m) and Connector Models | ||||
Weight (packed state) |
Pre-wired Models Model |
Approx. 60 g | Approx. 70 g | ||
Connector Models | Approx. 15 g | Approx. 25 g | |||
Materials | Case | Stainless steel (SUS303) | Nickel-plated brass | ||
Sensing surface | PBT | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washer | Zinc-plated iron | ||||
Accessories | Instruction manual |
Size | M18 | M30 | |||
---|---|---|---|---|---|
Shielded | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2E-X5Y[] | E2E-X10MY[] | E2E-X10Y[] | E2E-X18MY[] | |
Sensing distance | 5 mm ±10% | 10 mm ±10% | 18 mm ±10% | ||
Set distance | 0 to 4 mm | 0 to 8 mm | 0 to 14 mm | ||
Differential travel | 10% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) |
||||
Standard sensing object | Iron, 18 × 18 × 1 mm |
Iron, 30 × 30 × 1 mm | Iron, 54 × 54 × 1 mm |
||
Response frequency | 25 Hz | ||||
Power supply voltage (operating voltage range) *1 |
24 to 240 VAC (20 to 264 VAC), 50/60 Hz | ||||
Leakage current | 1.7 mA max. | ||||
Control output |
Load current *2 | 5 to 300 mA | |||
Residual voltage | Refer to Engineering Data on Data Sheet. | ||||
Indicators | Operation indicator (red) | ||||
Operation mode (with sensing object approaching) |
Y1 Models: NO Y2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. |
||||
Protection circuits | Surge suppressor | ||||
Ambient temperature range *1 *2 |
Operating/Storage: -40 to 85°C (with no icing or condensation) | ||||
Ambient humidity range | Operating/storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C, ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 4,000 VAC (M8 Models: 2,000 VAC), 50/60 Hz for 1 min between current-carrying parts and case |
||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | ||||
Degree of protection | Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant Connector Models: IEC 60529 IP67 |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m) and Connector Models | ||||
Weight (packed state) |
Pre-wired Models Model |
Approx. 130 g | Approx. 175 g | ||
Connector Models | Approx. 40 g | Approx. 90 g | |||
Materials | Case | Stainless steel (SUS303) | Nickel-plated brass | ||
Sensing surface | PBT | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washer | Zinc-plated iron | ||||
Accessories | Instruction manual |
*1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is at
least −25°C.
*2. When using an M18 or M30 Connector Model at an ambient temperature between 70 and 85°C, make sure that the
Sensor has a control output (load current) of 5 to 200 mA max.
E2E-X[]T1 AC/DC 2-Wire Models
Size | M12 | M18 | M30 | |
---|---|---|---|---|
Shielded | Shielded | |||
Model | E2E-X3T1 | E2E-X7T1 | E2E-X10T1 | |
Sensing distance | 3 mm ±10% | 7 mm ±10% | 10 mm ±10% | |
Set distance | 0 to 2.4 mm | 0 to 5.6 mm | 0 to 8 mm | |
Differential travel | 10% max. of sensing distance | |||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) |
|||
Standard sensing object | Iron, 12 × 12 × 1 mm | Iron, 18 × 18 × 1 mm | Iron, 30 × 30 × 1 mm | |
Response frequency *1 |
DC | 1 kHz | 0.5 kHz | 0.4 kHz |
AC | 25 Hz | |||
Power supply voltage (operating voltage range) *2 |
24 to 240 VDC (20 to 264 VDC) 48 to 240 VAC (40 to 264 VAC) |
|||
Leakage current | DC: 1 mA max. AC: 2 mA max. |
|||
Control output |
Load current | 5 to 100 mA | ||
Residual voltage |
DC: 6 V max. (Load current: 100 mA, Cable length: 2 m) AC: 10 V max. (Load current: 5 mA, Cable length: 2 m) |
|||
Indicators | Operation indicator (red), Setting indicator (green) | |||
Operation mode (with sensing object approaching) |
NO (Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.) | |||
Protection circuits | Load short-circuit protection (20 to 40 VDC only), Surge suppressor | |||
Ambient temperature range | Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | |||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | |||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | |||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | |||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||
Dielectric strength | 4,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | |||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
|||
Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | |||
Degree of protection | IEC 60529 IP67, in-house standards: oil-resistant | |||
Connection method | Pre-wired Models (Standard cable length: 2 m) | |||
Weight (packed state) | Approx. 80 g | Approx. 140 g | Approx. 190 g | |
Materials | Case | Nickel-plated brass | ||
Sensing surface | PBT | |||
Clamping nuts | Nickel-plated brass | |||
Toothed washer | Zinc-plated iron | |||
Accessories | Instruction manual |
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a
distance of twice the standard sensing object, and a set distance of half the sensing distance.
*2. Power Supply Voltage Waveform:
Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset.
E2E-X[]E[]/F[] DC 3-Wire Models
Size | M8 | M12 | |||
---|---|---|---|---|---|
Shielded | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2E-X1R5E[]/F[] | E2E-X2ME[]/F[] | E2E-X2E[]/F[] | E2E-X5ME[]/F[] | |
Sensing distance | 1.5 mm ±10% | 2 mm ±10% | 5 mm ±10% | ||
Set distance | 0 to 1.2 mm | 0 to 1.6 mm | 0 to 4 mm | ||
Differential travel | 10% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) |
||||
Standard sensing object | Iron, 8 × 8 × 1 mm |
Iron, 12 × 12 × 1 mm | Iron, 15 × 15 × 1 mm |
||
Response frequency *1 | 2 kHz | 0.8 kHz | 1.5 kHz | 0.4 kHz | |
Power supply voltage (operating voltage range) *2 |
12 to 24 VDC, ripple(p-p): 10% max. (10 to 30 VDC) Connector Models Used as UL-certified Models: 12 to 24 VDC, ripple (p-p): 10% max. (The operating voltage range is also the same.) *3 |
||||
Current consumption | 13 mA max. | ||||
Control output |
Load current *2 | 200 mA max. | |||
Residual voltage | 2 V max. (Load current: 200 mA, Cable length: 2 m) | ||||
Indicators | Operation indicator (red) | ||||
Operation mode (with sensing object approaching) |
E1/F1 Models: NO E2/F2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. |
||||
Protection circuits | Load short-circuit protection, Surge suppressor, Reverse polarity protection | ||||
Ambient temperature range *2 |
Operating/Storage: -40 to 85°C (with no icing or condensation) | ||||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case | ||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
Shock resistance | Destruction: 500 m/s2 10 times each in X, Y, and Z directions |
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions |
|||
Degree of protection | Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant Connector Models: IEC 60529 IP67 |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m) and Connector Models | ||||
Weight (packed state) |
Pre-wired Models | Approx. 65 g | Approx. 75 g | ||
Connector Models |
Approx. 15 g | Approx. 25 g | |||
Materials | Case | Stainless steel (SUS303) | Nickel-plated brass | ||
Sensing surface | PBT | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washer | Zinc-plated iron | ||||
Accessories | Instruction manual |
Size | M18 | M30 | |||
---|---|---|---|---|---|
Shielded | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2E-X5E[]/F[] | E2E-X10ME[]/F[] | E2E-X10E[]/F[] | E2E-X18ME[]/F[] | |
Sensing distance | 5 mm ±10% | 10 mm ±10% | 18 mm ±10% | ||
Set distance | 0 to 4 mm | 0 to 8 mm | 0 to 14 mm | ||
Differential travel | 10% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) |
||||
Standard sensing object | Iron, 18 × 18 × 1 mm |
Iron, 30 × 30 × 1 mm | Iron, 54 × 54 × 1 mm |
||
Response frequency *1 | 0.6 kHz | 0.2 kHz | 0.4 kHz | 0.1 kHz | |
Power supply voltage (operating voltage range) *2 |
12 to 24 VDC, ripple(p-p): 10% max. (10 to 30 VDC) Connector Models Used as UL-certified Models: 12 to 24 VDC, ripple (p-p): 10% max. (The operating voltage range is also the same.) *3 |
||||
Current consumption | 13 mA max. | ||||
Control output |
Load current *2 | 200 mA max. | |||
Residual voltage | 2 V max. (Load current: 200 mA, Cable length: 2 m) | ||||
Indicators | Operation indicator (red) | ||||
Operation mode (with sensing object approaching) |
E1/F1 Models: NO E2/F2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. |
||||
Protection circuits | Load short-circuit protection, Surge suppressor, Reverse polarity protection | ||||
Ambient temperature range *2 |
Operating/Storage: -40 to 85°C (with no icing or condensation) | ||||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case | ||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | ||||
Degree of protection | Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant Connector Models: IEC 60529 IP67 |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m) and Connector Models | ||||
Weight (packed state) |
Pre-wired Models | Approx. 150 g | Approx. 195 g | ||
Connector Models |
Approx. 40 g | Approx. 90 g | |||
Materials | Case | Nickel-plated brass | |||
Sensing surface | PBT | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washer | Zinc-plated iron | ||||
Accessories | Instruction manual |
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a
distance of twice the standard sensing object, and a set distance of half the sensing distance.
*2. When using an M8 Model at an ambient temperature between 70 and 85°C, supply 10 to 30 VDC to the Sensor and
make sure that the Sensor has a control output of 100 mA maximum.
*3. For the information on UL-certified connector models, refer to your OMRON website.
Order Code
Model List
-
2-Wire Models: Shielded DC 2-wire Models with No Self-diagnostic Output
E2E-X2D1-M1TGJ-U 0.3M
E2E-X2D2-M1TGJ-U 0.3M
E2E-X2D1-M1TGJ 0.3M
E2E-X2D1-U 2M
E2E-X2D2-U 2M
E2E-X2D1-N 2M
E2E-X2D2-N 2M
E2E-X2D1-M1G
E2E-X2D2-M1G
E2E-X2D1-M3G
E2E-X2D2-M3G
E2E-X3D1-M1TGJ-U 0.3M
E2E-X3D2-M1TGJ-U 0.3M
E2E-X3D1-M1TGJ 0.3M
E2E-X3D1-U 2M
E2E-X3D2-U 2M
E2E-X3D1-N 2M *1
E2E-X3D2-N 2M
E2E-X3D1-M1G *1
E2E-X3D2-M1G
E2E-X3D1-M1GJ 0.3M
E2E-X3D2-M1GJ 0.3M
E2E-X3D1-M1J-T 0.3M
E2E-X7D1-M1TGJ-U 0.3M
E2E-X7D2-M1TGJ-U 0.3M
E2E-X7D1-M1TGJ 0.3M
E2E-X7D1-U 2M
E2E-X7D2-U 2M
E2E-X7D1-N 2M *1
E2E-X7D2-N 2M
E2E-X7D1-M1G *1
E2E-X7D2-M1G
E2E-X7D1-M1GJ 0.3M
E2E-X7D2-M1GJ 0.3M
E2E-X7D1-M1J-T 0.3M
E2E-X7D2-M1J-T 0.3M
E2E-X10D1-M1TGJ-U 0.3M
E2E-X10D2-M1TGJ-U 0.3M
E2E-X10D1-M1TGJ 0.3M
E2E-X10D1-U 2M
E2E-X10D2-U 2M
E2E-X10D1-N 2M *1
E2E-X10D2-N 2M
E2E-X10D1-M1G *1
E2E-X10D2-M1G
E2E-X10D1-M1GJ 0.3M
E2E-X10D2-M1GJ 0.3M
E2E-X10D1-M1J-T 0.3M
E2E-X10D2-M1J-T 0.3M