Molded-case circuit breakers are used to open/close low-voltage circuits and protect wiring by automatically closing circuits when they’re overloaded or if a short-circuit occurs. We offer an economy, standard, high performance and current limiting breaker suitable for virtually every application.

Specification

Molded Case Circuit Breakers (50 -100AF)

Frame Size (A)

50

100

Model Number

NF50-SMU

NF50-SVFU

NF100-CVFU

NF100-SRU

NF100-HRU

Stocked Item

S

S

S

S

S

S

S

Rated Current in Amps at Ambient Temperature 40°C (IEC 30°C)

0.5 1(1.5) 2 3 4 5(6) 7 (8) 10 13 15 20(25) 30 (35) (40) 50

(0.5 ) (1)(1.5) (2) (3) 4 5 (6)(7) (8) 10 13 15 20 25 30 (35) 40 50

(3) 5 10 15 20 30 40 50

60 (70) 75 (80) (90) 100

(1) (2) 3 5 10 15 20 (25) 30 40 50 60 (70) 75 (80) (90) 100

(1) (2) 3 5 10 15 20 (25) 30 40 50 60 (70) 75 (80) (90) 100

Number of Poles

1

2

3

2

3

2

3

2

3

2

3

Rated Voltage

AC (V)

240

240

240

240

480

DC (V)

60

UL489 (File No. E108284) CSA C22.2
No. 5-02

AC

600Y / 347V

480V

18 (10)

480Y / 277V

240V

5

10

14

14

35

50 (25)

120V

10

DC

60V

10

Rated Insulation Voltage (Ui) V

440

440

600

500

500

JIS C
8201-2-1 Ann.1

IEC60947-2 EN60947-2 (Icu/Ics)

AC

690V

500V

7.5/4

10/5

18/9 (10/5)

440V

7.5/4

10/5

15/8

25/13 (15/8)

415V

10/5

10/5

15/8

25/13 (15/8)

400V

10/7.5

10/5

10/5

15/8

25/13 (15/8)

380V

10/5

10/5

230V

10/7.5

10/7.5

15/8

15/8

35/18 (25/13)

50/25 (25/13)

DC

250V

60V

10/7.5

Overall Dimensions mm (in)

Width

18

36

54

36

54

50

75

50

75

50

75

Height

124

120

150

120

120

Depth

44

68

68

68

74

Depth Including Knob

70

90

90

90

102

External Handles

F-Type

2P: F-03SVUL2
3P:F-03SVUL

2P: F-05SVUL2
3P:F-05SVUL

2P: F-05SRUL2

3P: F-05SRUL

V-Type

2P: V-03SVUL2
3P: V-03SVU

2P: V-05SVUL2
3P: V-05SVUL

2P: V-05SRUL2
3P: V-05SRUL

C-Type

3P: C1SVU

Handle Lock

HL

HLF-05SMU

HLF-03SVU

HLF-05SVU

HLF-05SRU

HL-S

HLS-03SVU

2P: HLS-05SVU2
3P: HLS-05SVU

2P: HLS-05SRU2
3P: HLS-05SRU3

Terminal Covers (TCL, TCS)

2P: TCL-03SVU2
3P: TCL-03SVU3

2P: TCL-05SVU2,
TCL-05SVU2L
3P: TCL-05SVU3,
TCL-05SVU3L

2P: TCS-05SRU2, TCL-05SRU2
3P: TCS-05SRU3, TCL-05SRU3
TCG-05SRU

Note: V-Type handles require a separate extension shaft, V-AD3S for 50AF to 250AF MCCB and the V-AD3L for 400AF to 630AF MCCB.

Molded Case Circuit Breakers (125 – 225AF)

Frame Size (A)

125

225

250

Model Number

NF125-SVU

NF125-HVU

NF225-CWU

Stocked Item

S

S

S

S

S

S

Rated Current in Amps at Ambient Temperature 40°C (IEC 30°C)

15 20 30 40 50 60 (70) 75 (80) (90) 100

125

15 20 30 40 50 60 (70) 75 (80)(90) 100

125

125 150 175

200 225

(250)

Number of Poles

2

3

2

3

3

3

3

3

Rated Voltage

AC (V)

480

480

600Y/347

240

240

DC (V)

UL489 (File No. E108284)
CSA C22.2
No. 5-02

AC

600Y / 347V

18

480V

30

30

50

480Y / 277V

240V

50

50

100

35

35

120V

DC

60V

Rated Insulation Voltage (Ui) V

690

690

690

600

600

JIS C
8201-2-1 Ann.1
IEC60947-2
EN60947-2
(Icu/Ics)

AC

690V

8/4

8/4

10/5

500V

18/9

18/9

25/13

10/5

440V

30/15

30/15

50/25

15/8

15/8

415V

30/15

30/15

50/25

18/9

18/9

400V

30/15

30/15

50/25

18/9

18/9

380V

30/15

30/15

50/25

18/9

18/9

230V

50/25

50/25

100/25

35/18

35/18

DC

250V

10/5

10/5

60V

Overall Dimensions mm (in)

Width

90

90

90

105

105

Height

160

160

160

165

165

Depth

68

68

68

68

68

Depth Including Knob

90

90

90

92

92

External Handles

F-Type

F-1SVUL

F-2SUL

V-Type

V-1SVUL

V-2SUL

S-Type

S2SWU

C-Type

C1SVU

C2SWU

Handle Lock

HL

HLF-05SVU

HLF-2SWU

HL-S

HLS-05SVU

HLS-2SWU

Mechanical Interlock

MI-05SWU3

Terminal Cover

TCL-1SVU3

TCL-2SWU3, TCL-2SWU3L

 

Molded Case Circuit Breakers (250AF – 630AF)

Frame Size (A)

250

400

630

Model Number

NF250-SVU

NF250-HVU

NF400-SWU

NF400-HWU

NF630-SWU

NF630-HWU

Stocked Item

S

S

S

S

S

S

S

S

Rated Current in Amps at Ambient Temperature 40°C (IEC 30°C)

125 150 175 200 225

250

125 150 175 200 225

250

250 300 350 400

250 300 350 400

500 600 630

500 600 630

Number of Poles

3

3

3

3

3

3

3

3

Rated Voltage

AC (V)

480

600Y/347

600Y/347

600Y/347

DC (V)

UL489 (File No. E108284)
CSA C22.2
No. 5-02

AC

600Y / 347V

18

20

25

20

25

480V

35

50

35

65

35

65

480Y / 277V

240V

65

100

65

100

85

100

120V

DC

60V

Rated Insulation Voltage (Ui) V

690

690

690

690

JIS C
8201-2-1 Ann.1
IEC60947-2
EN60947-2
(Icu/Ics)

AC

690V

8/4

10/5

10/10 (5/5)

15/10

10/10

15/10

500V

25/13

36/18

30/30 (25/25)

42/42

30/30

42/42

440V

36/18

50/25

42/42 (36/36)

65/65

42/42

65/65

415V

36/18

50/25

45/45 (36/36)

70/70

45/45

70/70

400V

36/18

50/25

45/45 (36/36)

70/70

45/45

70/70

380V

36/18

50/25

50/50 (42/42)

70/70

50/50

70/70

230V

65/33

100/50

85/85 (65/65)

100/100

85/85

100/100

DC

250V

60V

Overall Dimensions (mm)

Width

105

105

140

210

Height

185

185

257

275

Depth

68

68

103

103

Depth Including Knob

92

92

155

155

External Handles

F-Type

F-2SVUL

F-4SUL

F-6SUL

V-Type

V-2SVUL

V-4SUL

V-6SUL

C-Type

C2SVU

C4SWU

Handle Lock

HL

HLF-05SVU

HL-4SWU

HL-4SWU

HL-S

HLS-2SVU

HLS-2SVU

Terminal Cover

TCL-2SVU3, TCL-2SVU3L

TCL-4SWU

TCL-6SWU

Note: V-Type handles require a separate extension shaft, V-AD3S for 50AF to 250AF MCCB and the V-AD3L for 400AF to 630AF MCCB