Dòng biến tần FRENIC-Ace được sử dụng hầu hết cho các loại quạt công nghiệp, máy bơm .và cho các thiết bị máy móc đặc biệt.
Có 2 loại biến tần FRENIC-Ace
- Loại Three phase 200V : FRN □ E2S-2J
- Loại Single phase 200V: FRN □ E2S-7J
Tùy theo hệ thống điện của nhà máy mà khách hàng chọn loại thích hợp.
Specification
Three phase 200V class series
*1Fuji 4-pole standard motor. At the selection of the inverter rating, consider not only the rating capacity(kW) is enough but also inverter output current is larger than selected the motor’s nominal current.*2Rated capacity is calculated by assuming the output rated voltage as 220 V.*3Output voltage cannot exceed the power supply voltage.*4When the carrier frequency (F26) is set to below value or higher, the inverter is sure to be necessary to derate their nominal current.
HHD spec.—type 0001 to 0020 : 8kHz, type 0030 to 0115 : 10kHz,
HND spec.—type 0001 to 0020 : 4kHz, type 0030 to 0069 : 10kHz, type 0088,0115 : 4kHz*5The value is calculated assuming that the inverter is connected with a power supply with the capacity of 500 kVA
(or 10 times the inverter capacity if the inverter capacity exceeds 50 kVA) and %X is 5%.*6Obtained when a DC reactor (DCR) is used.*7Average braking torque for the motor running alone. (It varies with the efficiency of the motor.)*8Voltage unbalance (%) =(Max. voltage (V) – Min. voltage (V))/Three -phase average voltage (V) × 67 (IEC 61800 – 3)
If this value is 2 to 3%, use an optional AC reactor (ACR).*9HND spec. of the type 0012 and 0020: allowable ambient temperature 40 °C (+104 °F) or less.
The rated output current at HND spec. is decreased 1% for every 1 °C (1.8 °F) when ambient temperature is +40 °C (+104 °F) or more.
Single phase 200V class series
*1Fuji 4-pole standard motor. At the selection of the inverter rating, consider not only the rating capacity(kW) is enough but also inverter output current is larger than selected the motor’s nominal current.*2Rated capacity is calculated by assuming the output rated voltage as 220 V.*3Output voltage cannot exceed the power supply voltage.*4When the carrier frequency (F26) is set to below value or higher, the inverter is sure to be necessary to derate their nominal current.
HHD spec.—type 0001 to 0011 : 8kHz*5The value is calculated assuming that the inverter is connected with a power supply with the capacity of 500 kVA
(or 10 times the inverter capacity if the inverter capacity exceeds 50 kVA) and %X is 5%.*6Obtained when a DC reactor (DCR) is used.*7Average braking torque for the motor running alone. (It varies with the efficiency of the motor.)
Order Code
Order code cho mạng lưới điện 3-phase AC200V
FRN □ E2S-2J
Trong đó □ : là công suất biến tần
Order code cho mạng lưới điện single-phase AC200V
FRN □ E2S-7J
Model List
Loại 3-phase AC200V
FRN0.1E2S-2J
FRN0.2E2S-2J
FRN0.4E2S-2J
FRN0.75E2S-2J
FRN1.5E2S-2J
FRN2.2E2S-2J
FRN3.7E2S-2J
FRN5.5E2S-2J
FRN7.5E2S-2J
FRN11E2S-2J
FRN15E2S-2J
FRN18.5E2S-2J
FRN22E2S-2J
Loại single-phase AC200V
FRN0.1E2S-7J
FRN0.2E2S-7J
FRN0.4E2S-7J
FRN0.75E2S-7J
FRN1.5E2S-7J
FRN2.2E2S-7J