Max. operation distance | 2.5 mm 0.098 in plus or minus 20% (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. |
Stable sensing range | 0 to 1.8 mm 0 to 0.071 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. |
Standard sensing object | Iron sheet 15 × 15 × t 1 mm 0.591 × 0.591 × t 0.039 in |
Hysteresis | 20 % or less of operation distance(with standard sensing object) |
Repeatability | Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less |
Supply voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Current consumption | 0.8 mA or less (Note) It is the leakage current when the output is in the OFF state. |
Output | Non-contact DC 2-wire type – Load current: 3 to 70 mA (Note 1) – Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies with the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V. |
Output:Utilization category | DC-12 or DC-13 |