WL-N / WLG Limit Switch Vertical type

CÔNG TY TNHH KỸ THUẬT NTN
Mô tả sản phẩm

General-purpose Switches

A type with operation indicators for easily confirming operation is available

Indicates the operation status of the switches using LEDs and neon lamps.

WL-N / WL Features 3

Selectable based on wiring specifications

WL-N / WL Features 4

Environment-resistant Limit Switches


Ambient operating temperature of 5°C to 120°C: Heat-resistant type (WL[]-TH-N/WL[]-TH)
Ambient operating temperature of -40°C to 40°C: Cold-resistant type (WL[]-TC-N/WL[]-TC)

Select based on the operating environment

 

Outdoor use: Weather-resistant type (WL[]-P1-N/WL[]-P1)
Chemicals and oils: Corrosion-resistant type (WL[]-RP-N/WL[]-RP)
Coolant drops and mist: Coolant-resistant type (WL[]-RP60-N/WL-RP60)
Mist
Molded terminal 139 type (WL[]-139-N/WL[]-139)
The SC connector can be removed, so it is possible to use flexible conduit for the cable.
(WL[]-RP40-N/WL-RP40)
Constant water drops and mist Molded terminal 140 type (WL[]-140-N/WL[]-140)
Constant water drops or splattering cutting powder
Molded terminal 141 type (WL[]-141-N/WL[]-141)
Molded terminal 145 type (WL[]-145-N/WL[]-145)

 

Spatter-prevention Switches

Structure designed for use in spattering environments from welding (Typical model: WLCA2-LDS-N)

WL-N / WL Features 9

Long-life Switches

Mechanical structure featuring mechanical durability of more than 30 million operations (WLMCA2-N)

WL-N / WL Features 11

Specification

Screw terminals

Without Operation Indicator

Basic models (WL-N)

 
Ratings Non-inductive load (A) Inductive load (A)
Basic models (WL-N) Basic models (WL-N)
Resistive load Lamp load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO
AC 125 10 3 1.5 10 5 2.5
250 10 2 1 10 3 1.5
500 10 1.5 0.8 3 1.5 0.8
DC 8 10 6 3 10 6
14 10 6 3 10 6
30 6 4 3 6 4
125 0.8 0.2 0.2 0.8 0.2
250 0.4 0.1 0.1 0.4 0.1
 

High-sensitivity and High-precision models (WLG)

 
Ratings Non-inductive load (A)
High-sensitivity and High-precision models (WLG)
Resistive load
Voltage (V) NC NO
AC 125 5
250 5
DC 125 0.4
250 0.2
 

With Operation Indicator (LED)

Basic models (WL-N)

 
Ratings Non-inductive load (A) Inductive load (A)
Basic models (WL-N) Basic models (WL-N)
Resistive load Lamp load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO
AC 115 10 3 1.5 10 5 2.5
DC 12 10 6 3 10 6
24 6 4 3 6 4
48 3 2 1.5 3 0.2
115 0.8 0.2 0.8 0.1
 

High-sensitivity and High-precision models (WLG)

 
Ratings Non-inductive load (A)
High-sensitivity and High-precision models (WLG)
Resistive load
Voltage (V) NC NO
AC 115 5
DC 115 0.4
 

With Operation Indicators (Neon Lamps)

Basic models (WL-N)

 
Ratings Non-inductive load (A) Inductive load (A)
Basic models (WL-N) Basic models (WL-N)
Resistive load Lamp load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO
AC 125 10 3 1.5 10 5 2.5
250 10 2 1 10 3 1.5
 

High-sensitivity and High-precision models (WLG)

 
Ratings Non-inductive load (A)
High-sensitivity and High-precision models (WLG)
Resistive load
Voltage (V) NC NO
AC 125 5
250 5
 
 
Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. A lamp load has an inrush current of 10 times the steady-state current. 4. A motor load has an inrush current of 6 times the steady-state current.
 

Allowable Inrush Current/Minimum Applicable Load

 
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision models (WLG)
Inrush current NC 30 A max. 15 A max.
NO 20 A max. 10 A max.
Minimum applicable load 5 VDC 1 mA, resistive load, P level 5 VDC 1 mA, resistive load, P level
 

Operation Indicator

 
Operation indicator type LED Neon lamp
Rated voltage 10 to 115 VAC/DC 125 to 250 VAC
Leakage current (Reference value) Approx. 0.4 mA at 10 VAC/DC Approx. 0.5 mA at 115 VAC/DC Approx. 0.6 mA at 125 VAC Approx. 1.9 mA at 250 VAC
 

Direct-wired connector and Pre-wired Connector Type

Connector DC Specifications: With Operation Indicators (LEDs)

Basic models (WL-N)

 
Ratings Non-inductive load (A) Inductive load (A)
Basic models (WL-N) Basic models (WL-N)
Resistive load Lamp load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO
DC 12 3 3 3 3
24 3 3 3 3
48 4 2 1.5 3 2
115 0.8 0.2 0.2 0.8 0.2
 

High-sensitivity and High-precision models (WLG)

 
Ratings Non-inductive load (A)
High-sensitivity and High-precision models (WLG)
Resistive load
Voltage (V) NC NO
DC 115 0.4
 

Connector AC Specifications: With Operation Indicators (LEDs)

Basic models (WL-N)

 
Ratings Non-inductive load (A) Inductive load (A)
Basic models (WL-N) Basic models (WL-N)
Resistive load Lamp load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO
AC 115 3 3 1.5 3 3 2.5
 

High-sensitivity and High-precision models (WLG)

 
Ratings Non-inductive load (A)
High-sensitivity and High-precision models (WLG)
Resistive load
Voltage (V) NC NO
AC 115 3
 
 
Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. A lamp load has an inrush current of 10 times the steady-state current. 4. A motor load has an inrush current of 6 times the steady-state current.
 

Minimum Applicable Load

 
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision models (WLG)
Minimum applicable load 5 VDC 1 mA, resistive load, P level 5 VDC 1 mA, resistive load, P level
 

Operation Indicator

 
Operation indicator type LED Neon lamp
Rated voltage 10 to 115 VAC/DC 125 to 250 VAC
Leakage current (Reference value) Approx. 0.4 mA at 10 VAC/DC Approx. 0.5 mA at 115 VAC/DC Approx. 0.6 mA at 125 VAC Approx. 1.9 mA at 250 VAC
 

Characteristics

 
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision models (WLG)
Permissible operating frequency Mechanical 120 operations/minute
Electrical 30 operations/minute
Rated frequency 50/60 Hz
Permissible operating speed 1 mm/s to 1 m/s (in case of WLCA2-N)
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 25 mΩ max. (initial value for the built-in switch)
Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock Destruction 1,000 m/s2 max.
Malfunction 300 m/s2 max. *2
Durability *1 Mechanical 15,000,000 operations min. 10,000,000 operations min.
Electrical 750,000 operations min. (3 A at 250 VAC, resistive load), but for high- precision models: *3 500,000 operations min. (3 A at 250 VAC, resistive load), but for high- precision models: *3
Ambient operating temperature -10 to +80°C (with no icing)
Ambient operating humidity 35 to 95%RH
Degree of protection IP67
Weight Approx. 255 g (in case of WLCA2-N) Approx. 270 g (in case of WLGCA2)
 
 
Note: The above figures are initial values. *1. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments. *2. Except Switches with Flexible Rod Actuators. *3. In case of Screw terminals without operation indicators.
 
 
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision models (WLG)
Wiring Specifications Screw terminals Direct-wire connector/ Pre-wired Connector Models Screw terminals Direct-wire connector/ Pre-wired Connector Models
Dielectric strength Between terminals of the same polarity 1,000 VAC, 50/60 Hz for 1 min * 600 VAC, 50/60 Hz for 1 min * 600 VAC, 50/60 Hz for 1 min * 600 VAC, 50/60 Hz for 1 min *
Between current- carrying metal part and ground 2,200 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min
Between each terminal and non- current-carrying metal part 2,200 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min
 
* Excluding those with operation indicators.

Environment-resistant Limit Switches

Ratings

Screw terminals/Direct-wire cable

Without Operation Indicator

Basic models (WL-N)

 
Ratings Non-inductive load (A) Inductive load (A)
Basic models (WL-N) Basic models (WL-N)
Resistive load Lamp load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO
AC 125 10 3 1.5 10 5 2.5
250 10 2 1 10 3 1.5
500 10 1.5 0.8 3 1.5 0.8
DC 8 10 6 3 10 6
14 10 6 3 10 6
30 6 4 3 6 4
125 0.8 0.2 0.2 0.8 0.2
250 0.4 0.1 0.1 0.4 0.1
 

High-sensitivity and High-precision models (WLG)

 
Ratings Non-inductive load (A)
High-sensitivity and High-precision models (WLG)
Resistive load
Voltage (V) NC NO
AC 125 5
250 5
DC 125 0.4
250 0.2
 

With Operation Indicator (LED)

Basic models (WL-N)

 
Ratings Non-inductive load (A) Inductive load (A)
Basic models (WL-N) Basic models (WL-N)
Resistive load Lamp load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO
AC 115 10 3 1.5 10 5 2.5
DC 12 10 6 3 10 6
24 6 4 3 6 4
48 3 2 1.5 3 0.2
115 0.8 0.2 0.8 0.1
 

High-sensitivity and High-precision models (WLG)

 
Ratings Non-inductive load (A)
High-sensitivity and High-precision models (WLG)
Resistive load
Voltage (V) NC NO
AC 115 5
DC 115 0.4
 

With Operation Indicators (Neon Lamps)

Basic models (WL-N)

 
Ratings Non-inductive load (A) Inductive load (A)
Basic models (WL-N) Basic models (WL-N)
Resistive load Lamp load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO
AC 125 10 3 1.5 10 5 2.5
250 10 2 1 10 3 1.5
 

High-sensitivity and High-precision models (WLG)

 
Ratings Non-inductive load (A)
High-sensitivity and High-precision models (WLG)
Resistive load
Voltage (V) NC NO
AC 125 5
250 5
 
 
Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. A lamp load has an inrush current of 10 times the steady-state current. 4. A motor load has an inrush current of 6 times the steady-state current.
 

Allowable Inrush Current/ Minimum applicable load

 
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision models (WLG)
Inrush current NC 30 A max. 15 A max.
NO 20 A max. 10 A max.
Minimum applicable load 5 VDC 1 mA, resistive load, P level 5 VDC 1 mA, resistive load, P level
 

Operation Indicator

 
Operation indicator type LED Neon lamp
Rated voltage 10 to 115 VAC/DC 125 to 250 VAC
Leakage current (Reference value) Approx. 0.4 mA at 10 VAC/DC Approx. 0.5 mA at 115 VAC/DC Approx. 0.6 mA at 125 VAC Approx. 1.9 mA at 250 VAC
 

Characteristics

 
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision models (WLG)
Permissible operating frequency Mechanical 120 operations/minute
Electrical 30 operations/minute
Rated frequency 50/60 Hz
Permissible operating speed 1 mm/s to 1 m/s (in case of WLCA2-N)
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 25 mΩ or less (default value, built-in switch only)
Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude *2
Shock Destruction 1,000 m/s2 max.
Malfunction 300m/s2 max. *2
Durability *1 Mechanical 15,000,000 operations min. 10,000,000 operations min. *3
Electrical 750,000 operations min. (3 A at 250 VAC, resistive load) *4 500,000 operations min. (3 A at 250 VAC, resistive load) *4
Ambient operating temperature -10 to +80°C (with no icing) *5
Ambient operating humidity 35 to 95%RH
Degree of protection IP67
Weight Approx. 250 g (for WLCL-TH-N) Approx. 250 g (for WLCL-TH-N)
 
 
Note: The above figures are initial values. *1. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments. *2. Except Switches with Flexible Rod Actuators. *3. 500,000 operations min. for Weather-resistant models. *4. In case of models without operation indicators. *5. For low-temperature models this is -40°C to +40°C (with no icing). For heat-resistant models the range is +5°C to 120°C.
 
 
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision models (WLG)
Wiring Specifications Screw terminals/ Direct-wire cable models Screw terminals/ Direct-wire cable models
Dielectric strength Between terminals of the same polarity 1,000 VAC, 50/60 Hz for 1 min * 600 VAC, 50/60 Hz for 1 min *
Between current-carrying metal part and ground 2,200 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min
Between each terminal and non- current-carrying metal part 2,200 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min
 
* Except models with operation indicators.

Spatter-prevention Switches

Ratings

Screw terminals

With Operation Indicator

Basic models (WL-N)

 
Ratings Non-inductive load (A) Inductive load (A)
Basic models (WL-N) Basic models (WL-N)
Resistive load Lamp load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO
AC 115 10 3 1.5 10 5 2.5
DC 12 10 6 3 10 6
24 6 4 3 6 4
48 3 2 1.5 3 0.2
115 0.8 0.2 0.8 0.1
 

High-sensitivity and High-precision models (WLG)

 
Ratings Non-inductive load (A)
High-sensitivity and High-precision models (WLG)
Resistive load
Voltage (V) NC NO
AC 115 5
DC 115 0.4
 

With Operation Indicators (Neon Lamps)

Basic models (WL-N)

 
Ratings Non-inductive load (A) Inductive load (A)
Basic models (WL-N) Basic models (WL-N)
Resistive load Lamp load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO
AC 125 10 3 1.5 10 5 2.5
250 10 2 1 10 3 1.5
 

High-sensitivity and High-precision models (WLG)

 
Ratings Non-inductive load (A)
High-sensitivity and High-precision models (WLG)
Resistive load
Voltage (V) NC NO
AC 125 5
250 5
 
 
Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. A lamp load has an inrush current of 10 times the steady-state current. 4. A motor load has an inrush current of 6 times the steady-state current.
 

Allowable Inrush Current/Minimum Applicable Load

 
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision models (WLG)
Inrush current NC 30 A max. 15 A max.
NO 20 A max. 10 A max.
Minimum applicable load 5 VDC 1 mA, resistive load, P level 5 VDC 1 mA, resistive load, P level
 

Operation Indicator

 
Operation indicator type LED Neon lamp
Rated voltage 10 to 115 VAC/DC 125 to 250 VAC
Leakage current (Reference value) Approx. 0.4 mA at 10 VAC/DC Approx. 0.5 mA at 115 VAC/DC Approx. 0.6 mA at 125 VAC Approx. 1.9 mA at 250 VAC
 

Pre-wired connectors

Connector DC Specifications: With Operation Indicators (LEDs)

Basic models (WL-N)

 
Ratings Non-inductive load (A) Inductive load (A)
Basic models (WL-N) Basic models (WL-N)
Resistive load Lamp load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO
DC 12 3 3 3 3
24 3 3 3 3
48 4 2 1.5 3 2
115 0.8 0.2 0.2 0.8 0.2
 

High-sensitivity and High-precision models (WLG)

 
Ratings Non-inductive load (A)
High-sensitivity and High-precision models (WLG)
Resistive load
Voltage (V) NC NO
DC 115 0.4
 
 
Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. A lamp load has an inrush current of 10 times the steady-state current. 4. A motor load has an inrush current of 6 times the steady-state current
 

Minimum Applicable Load

 
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision models (WLG)
Minimum applicable load 5 VDC 1 mA, resistive load, P level 5 VDC 1 mA, resistive load, P level
 

Operation Indicator

 
Operation indicator type LED Neon lamp
Rated voltage 10 to 115 VAC/DC 125 to 250 VAC
Leakage current (Reference value) Approx. 0.4 mA at 10 VAC/DC; Approx. 0.5 mA at 115 VAC/DC Approx. 0.6 mA at 125 VAC; Approx. 1.9 mA at 250 VAC
 

Characteristics

 
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision models (WLG)
Permissible operating frequency Mechanical 120 operations/minute
Electrical 30 operations/minute
Rated frequency 50/60 Hz
Permissible operating speed 1 mm/s to 1 m/s (for WLCA2-LDS-N)
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 25 mΩ max. (initial value for the built-in switch)
Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock Destruction 1,000 m/s2 max.
Malfunction 300 m/s2 max.
Durability * Mechanical 15,000,000 operations min. 10,000,000 operations min.
Electrical 750,000 operations min. (3 A at 115 VAC, resistive load) *2 500,000 operations min. (3 A at 115 VAC, resistive load) *2
Ambient operating temperature -10 to +80°C (with no icing)
Ambient operating humidity 35 to 95%RH
Degree of protection IP67
Weight Approx. 255 g (in case of WLCA2- LDS-N) Approx. 270 g (in case of WLGCA2- LDS)
 
 
Note: The above figures are initial values. *1. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments. *2. In case of models with operation indicators (LEDs).
 
 
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision models (WLG)
Wiring Specifications Screw terminals Direct-wire connector and Pre-wired Connector Models Screw terminals Direct-wire connector and Pre-wired Connector Models
Dielectric strength Between terminals of the same polarity 1,000 VAC, 50/60 Hz for 1 min * 600 VAC, 50/60 Hz for 1 min * 600 VAC, 50/60 Hz for 1 min * 600 VAC, 50/60 Hz for 1 min *
Between current- carrying metal part and ground 2,200 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min
Between each terminal and non- current carrying metal part 2,200 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min
 
* Excluding those with operation indicators.

Long-life Switches

Ratings

Screw terminals

With Operation Indicator

Basic models (WL-N)

 
Ratings Non-inductive load (A) Inductive load (A)
Basic models (WL-N) Basic models (WL-N)
Resistive load Lamp load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO
AC 115 10 3 1.5 10 5 2.5
DC 12 10 6 3 10 6
24 6 4 3 6 4
48 3 2 1.5 3 0.2
115 0.8 0.2 0.8 0.1
 

High-sensitivity and High-precision models (WLG)

 
Ratings Non-inductive load (A)
High-sensitivity and High-precision models (WLG)
Resistive load
Voltage (V) NC NO
AC 115 5
DC 115 0.4
 
 
Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. A lamp load has an inrush current of 10 times the steady-state current. 4. A motor load has an inrush current of 6 times the steady-state current.
 

Allowable Inrush Current/Minimum Applicable Load

 
Operating characteristics type Basic models (WL-N) High-sensitivity/ High-precision models (WLG)
Inrush current NC 30 A max. 15 A max.
NO 20 A max. 10 A max.
Minimum applicable load 5 VDC 1 mA, resistive load, P level 5 VDC 1 mA, resistive load, P level
 

Operation Indicator

 
Operation indicator type LED Neon lamp
Rated voltage 10 to 115 VAC/DC 125 to 250 VAC
Leakage current (Reference value) Approx. 0.4 mA at 10 VAC/DC; Approx. 0.5 mA at 115 VAC/DC Approx. 0.6 mA at 125 VAC; Approx. 1.9 mA at 250 VAC
 

Direct-wire connector and Pre-wired Connector Models Type

DC Connector: With Operation Indicators (LEDs)

Basic models (WL-N)

 
Ratings Non-inductive load (A) Inductive load (A)
Basic models (WL-N) Basic models (WL-N)
Resistive load Lamp load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO
DC 12 3 3 3 3
24 3 3 3 3
48 4 2 1.5 3 2
115 0.8 0.2 0.2 0.8 0.2
 

High-sensitivity and High-precision models (WLG)

 
Ratings Non-inductive load (A)
High-sensitivity and High-precision models (WLG)
Resistive load
Voltage (V) NC NO
DC 115 0.4
 

AC Connector: With Operation Indicators (LEDs)

Basic models (WL-N)

 
Ratings Non-inductive load (A) Inductive load (A)
Basic models (WL-N) Basic models (WL-N)
Resistive load Lamp load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO
AC 115 3 3 1.5 3 3 2.5
 

High-sensitivity and High-precision models (WLG)

 
Ratings Non-inductive load (A)
High-sensitivity and High-precision models (WLG)
Resistive load
Voltage (V) NC NO
AC 115 3
 
 
Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. A lamp load has an inrush current of 10 times the steady-state current. 4. A motor load has an inrush current of 6 times the steady-state current.
 

Minimum Applicable Load

 
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision models (WLG)
Minimum applicable load 5 VDC 1 mA, resistive load, P level 5 VDC 1 mA, resistive load, P level
 

Operation Indicator

 
Operation indicator type LED
Rated voltage 10 to 115 VAC/DC
Leakage current (Reference value) Approx. 0.4 mA at 10 VAC/DC; Approx. 0.5 mA at 115 VAC/DC
 

Characteristics

 
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision models (WLG)
Permissible operating frequency Mechanical 120 operations/minute
Electrical 30 operations/minute
Rated frequency 50/60 Hz
Permissible operating speed 1 mm/sec to 1 m/sec
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 25 mΩ max. (initial value for the built-in switch)
Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock Destruction 1,000 m/s2 max.
Malfunction 300 m/s2 max.
Durability * Mechanical 30,000,000 operations min.
Electrical 30,000,000 operations min. (10 mA at 24 VAC, resistive load) 750,000 operations min. (3 A at 115 VAC, resistive load) 500,000 operations min. (3 A at 115 VAC, resistive load)
Ambient operating temperature -10 to +80°C (with no icing)
Ambient operating humidity 35 to 95%RH
Degree of protection IP67
Weight Approx. 255 g (in case of WLMCA2-LD-N) Approx. 270 g (in case of WLMGCA2-LD)
 
 
Note: The above figures are initial values. * The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments.
 
 
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision models (WLG)
Wiring Specifications Screw terminals Direct-wire connector and Pre-wired Connector Models Screw terminals Direct-wire connector and Pre-wired Connector Models
Dielectric strength Between terminals of the same polarity 1,000 VAC, 50/60 Hz for 1 min * 600 VAC, 50/60 Hz for 1 min * 600 VAC, 50/60 Hz for 1 min * 600 VAC, 50/60 Hz for 1 min *
Between current- carrying metal part and ground 2,200 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min
Between each terminal and non- current-carrying metal part 2,200 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min
 
* Excluding those with operation indicators.

Common Specifications

General-purpose/Environment-resistant/Spatter-prevention/Long-life Switches

Approved Standards

 
Agency Standard File No. Approved models
UL UL508 Contact your OMRON representative for information Contact your OMRON representative for information
CSA cUL CSA C22.2 No.14
TÜV Rheinland EN60947-5-1
CCC (CQC) GB/T14048.5
 

Approved Standard Ratings

UL/cUL, CSA (UL508, CSA C22.2 No.14)

 
Specifications Approved Standards
Operation Indicator Sensor I/O connectors Item
No indicator No Connector Basic models A600 1 A, 125 VDC
High-sensitivity and High-precision models B600 0.5 A,125 VDC
Pre-wired Connector (AC) Basic, High-sensitivity or High-precision models C300 3 A, 250 VAC
Pre-wired Connector (DC) Direct-wired Connector (DC) Basic models 1 A, 125 VDC
High-sensitivity and High-precision models 0.5 A, 125 VDC
Neon lamp No Connector Basic models A300 10 A, 250 VAC
High-sensitivity and High-precision models B300 0.5 A, 250 VAC
Pre-wired Connector (AC) Basic, High-sensitivity or High-precision models C300 3 A, 250 VAC
LED No Connector Basic models A150 10 A, 115 VAC 1 A, 115 VDC
High-sensitivity and High-precision models B150 5 A, 115 VAC 0.5 A, 115 VDC
Pre-wired Connector (AC) Basic, High-sensitivity or High-precision models C150 3 A, 115 VAC
Pre-wired Connector (DC) Direct-wired Connector (DC) Basic models 1 A, 115 VDC
High-sensitivity and High-precision models 0.5 A, 115 VDC
 

A600 Authentication conditions

 
Rated voltage Carrying current Current (A) Volt-ampere (VA)
Make Break Make Break
120 VAC 240 VAC 480 VAC 600 VAC 10 A 60 30 15 12 6 3 1.5 1.2 7,200 720
 

C300 Authentication conditions

 
Rated voltage Carrying current Current (A) Volt-ampere (VA)
Make Break Make Break
120 VAC 240 VAC 2.5 A 15 7.5 1.5 0.75 1,800 180
 

A300 Authentication conditions

 
Rated voltage Carrying current Current (A) Volt-ampere (VA)
Make Break Make Break
120 VAC 240 VAC 10 A 60 30 6 3 7,200 720
 

A150 Authentication conditions

 
Rated voltage Carrying current Current (A) Volt-ampere (VA)
Make Break Make Break
120 VAC 10 A 60 6 7,200 720
 

C150 Authentication conditions

 
Rated voltage Carrying current Current (A) Volt-ampere (VA)
Make Break Make Break
120 VAC 2.5 A 15 1.5 1,800 180
 

B600 Authentication conditions

 
Rated voltage Carrying current Current (A) Volt-ampere (VA)
Make Break Make Break
120 VAC 240 VAC 480 VAC 600 VAC 5 A 30 15 7.5 6 3 1.5 0.75 0.6 3,600 360
 

B300 Authentication conditions

 
Rated voltage Carrying current Current (A) Volt-ampere (VA)
Make Break Make Break
120 VAC 240 VAC 5 A 30 15 3 1.5 3,600 360
 

B150 Authentication conditions

 
Rated voltage Carrying current Current (A) Volt-ampere (VA)
Make Break Make Break
120 VAC 5 A 30 3 3,600 360
 

TÜV (EN 60947-5-1)

 
Authentication conditions Specification
Direct-wire cable type With Prewired DC connector model
No indicator Neon lamp LED
Working load category AC-15 DC-12 AC-15 AC-15 DC-12 DC-12
Rated working voltage (Ue) 250 V 48 V 250 V 115 V 48 V 48 V
Rated working current (Ie) 2 A
Conditional short-circuit current 100 A
Short-circuit protective device (SCPD) 10 A, fuse type gG
Rated insulation voltage (Ui) 250 V 48 V
Rated impulse dielectric strength (Uimp) 4 kV 800 V
Pollution degree 3
Electric shock protection class Class I Class III
 

CCC (GB/T14048.5)

 
Authentication conditions Specification
No indicator Neon lamp LED With Prewired DC connector model With Prewired AC connector model
Working load category AC-15 DC-13 AC-15 AC-15 DC-13 DC-13 AC-15
Rated working voltage (Ue) 250 V 48 V 250 V 250 V 48 V 48 V 250 V
Rated working current (Ie) 2 A
Conditional short-circuit current 1000 A
Short-circuit protective device (SCPD) 10 A, fuse type gG
Rated insulation voltage (Ui) 250 V

Order Code